DOWNLOAD/INSTALL INSTRUCTIONS: CFA-24 FIRMWARE UPGRADE

NOTE: Upgrading the firmware resets the Coordinate Matrix to the factory default settings (if the Retain Current Settings box is not checked). Prior to performing this procedure, backup the Coordinate Matrix settings (see Create Backup of Coordinate Matrix in the product manual).

This process can take as long as 50 minutes, depending on the connection speed on the CFA-24 network.

Telebyte recommends the use of Google Chrome browser (version-11.0.9600.17937 & update versions -11.0.22) for the most stability.

Download and unzip the firmware upgrade package on the remote PC

DOWNLOAD LINK:     CFA-24 Control Center Software v7.8.1

  • NOTE: Unzipping the firmware upgrade package is extremely important. The upgrade will fail otherwise.

  • -Enter the static IP address of the unit to access the Main screen.
  • -Select Upgrade Firmware.

  • The Main Screen. Software version shown is an example only.

  • The Upgrade Firmware screen is displayed.
     

 The Upgrade Firmware screen. Software version shown is an example only.

  • -Select Firmware File: click Choose File to search for and select the remote PC that contains the firmware file. The filename of CFA-x.x.x.telebyte (where x.x.x represents the new firmware version) should be available for selection.
  • -Check off Retain Current Settings: Retains all settings from the Initial Configuration Management, including IP settings, Operational Mode, and Coordinate Matrix.

  •  UPGRADE:
    Click the UPGRADE button to begin the firmware upgrade. The following screen is shown:

 

 


  •  This above screen displays for approximately10 minutes. The following screen is then shown:


 

 

  • The above screen may not display “. . . 40 to 50 minutes . . .” but instead may show “this process may take a few minutes.”

 

  • A progress bar is displayed. The message “Firmware upgraded successfully” is shown when the firmware upgrade is complete. See the following screen for an example.

 


 

  • -Press OK and wait 3 minutes for the system to reboot. During this time, the web browser displays a message indicating the web page is unavailable.

 

  • -When the reboot is complete, type the IP address of the CFA system into the web browser to reestablish the connection. The Main screen appears with the new version number displayed at the bottom of the screen.